Gear Flow Meter Standard / Acid Catalyst - Intelliflow RM2 and RF2
Gear Flow Meter for the Intelliflow RM2 and RF2
Manufacturer: Ransburg
Part #: 310-9000 or 310-9002
Description: The Ransburg 310-9000 gear-type flow meter is developed to precisely meter and monitor fluid flows. This flow meter, in many cases, surpasses the performance of other types of meters currently used.
A flow rate accuracy of 0.5% is typical with many fluids if the flow meter is calibrated at or near the expected flow rates. Even with wide flow rate swings (such as when used with robots under analog control), an accuracy of ± 2% is possible.
| Parts and Accessories: |
![]() |
| Ref. No. | Part No. | Description | QTY |
| 1 | 310-9010 | Flow Meter Body (contains 1, 2, 11, 12, and 13) | 1 |
| 2 | 310-9020 | Socket Head Cap Screws | 6 |
| 3 | 310-9011 | Dual Probe Pickup Sensor | 1 |
| 4 | 310-9012 | Fiber Optic Pickup Sensor | 1 |
| 5 | - | Socket Head Cap Screw | 2 |
| 6 | - | Washer, Lock, Ext. Tooth | 2 |
| 7 | - | Washer, Flat | 2 |
| 8 | - | Flow Meter Mounting Bracket | 1 |
| 9 | - | Flow Meter Mounting Bracket | 1 |
| 10 | - | Fitting, 1/4” NPS (M) X 3/8” JIC (M) | 2 |
| 11 | 310-9016 | Shaft, Flow Meter | 2 |
| 12 | 310-9015 | Gear, Flow Meter | 2 |
| 13 | 310-9017 | Seals, Flow Meter | 1 |
| 14 | - | Fiber Optic Sensor Battery | 1 |